Petrol Generators "Vepr": 5 KW, 6 KW And Other Power. How To Choose A Gasoline Generator?

Table of contents:

Petrol Generators "Vepr": 5 KW, 6 KW And Other Power. How To Choose A Gasoline Generator?
Petrol Generators "Vepr": 5 KW, 6 KW And Other Power. How To Choose A Gasoline Generator?
Anonim

Although rolling blackouts are a thing of the past, power grids are still vulnerable to breakdowns. In addition, the power grid is not available everywhere in principle, which worsens the quality of life in the dachas. Therefore, when creating a main or backup power supply system for a country house or industrial facility, it is worthwhile to review the Vepr gasoline generators and familiarize yourself with their main differences from competitors.

Image
Image
Image
Image

Peculiarities

The history of the Russian company Vepr began in 1998, when a company was created in Kaluga on the basis of the Babyninsky Electromechanical Plant, which was engaged in the supply of the plant's products (including electric generators) to the markets of the CIS and the Baltic countries.

Today the Vepr group of companies produces about 50,000 generators a year, and its factories are located not only in Kaluga, but also in Moscow and Germany.

Image
Image
Image
Image

The main advantages of gasoline generators over diesel and gas:

  • low noise level (70 dB maximum);
  • low (especially in comparison with gas options) price;
  • ease of purchasing fuel (getting diesel fuel, the more liquefied gas is not possible at every gas station);
  • safety (in terms of fire hazard, gasoline is noticeably safer than gas, although it is more dangerous than diesel fuel);
  • environmental friendliness (exhaust gases of gasoline engines contain less soot than diesel exhaust);
  • tolerance to a certain amount of impurities in the fuel (a diesel engine may fail due to low-quality fuel).
Image
Image
Image
Image

This solution also has a number of disadvantages, the main ones of which are:

  • a relatively small resource of work before the planned overhaul;
  • low autonomy (after 5-10 hours of continuous operation, it is imperative to make a two-hour pause);
  • expensive fuel (both diesel fuel and gas will be cheaper, especially given the relatively high consumption of gasoline engines and their lower efficiency);
  • expensive repairs (diesel options are simpler, therefore cheaper to maintain).
Image
Image
Image
Image

The main differences between the Vepr petrol generators from the products of other companies:

  • small weight and dimensions - when designing generators, the company pays great attention to their portability, so that almost all current models have an open design;
  • reliability - due to the location of production facilities in the Russian Federation and Germany, the Vepr generators rarely fail, the use of modern durable materials in the structure reduces the risks of mechanical damage to products during transportation and operation;
  • efficient and high quality engine - the "heart" of the generators are motors of such well-known companies as Honda and Briggs-Stratton;
  • affordable price - Russian power generators will cost less than the products of German and American firms and only slightly more expensive than their Chinese counterparts;
  • unpretentiousness to fuel - any petrol generator "Vepr" can operate on both the AI-95 and the AI-92;
  • service availability - there are official dealers and service centers of the company in almost all large cities of the Russian Federation, in addition, the company has representative offices in the Baltic countries and the CIS.
Image
Image
Image
Image

Model overview

Currently, the Vepr company offers such models of gasoline generators

  • ABP 2, 2-230 VX - budget portable single-phase open version, recommended by the manufacturer for hiking and back-up systems. Power 2 kW, autonomous operation up to 3 hours, weight 34 kg. Launched manually.
  • ABP 2, 2-230 VKh-B - differs from the previous version by an enlarged gas tank, due to which the battery life is almost 9 hours, while the weight has increased only to 38 kg.
  • ABP 2, 7-230 VX - differs from the ABP 2, 2-230 VX model with increased rated power up to 2.5 kW. Duration of work without refueling 2, 5 hours, weight 37 kg.
  • ABP 2, 7-230 VKh-B - modernization of the previous model with a more capacious gas tank, which made it possible to extend the battery life up to 8 hours with the weight increased to 41 kg.
  • ABP 4, 2-230 VH-BG - differs from UPS 2, 2-230 VX in power, which for this model is 4 kW. Autonomous operation time - up to 12.5 h, generator weight 61 kg. Another difference is the maximum noise level reduced to 68 dB (for most other Vepr generators this figure is 72-74 dB).
  • ABP 5-230 VK - portable, open, single-phase version, recommended by the manufacturer for use on construction sites or for powering country houses. Rated power 5 kW, battery life 2 hours, product weight 75 kg.
  • ABP 5-230 VX - differs from the previous model in increased battery life up to 3 hours, as well as in a wider base, due to which its stability was increased when installed on unprepared ground (for example, during a hike or at a construction site).
  • ABP 6-230 VH-BG - differs from the previous model with a rated power increased to 5.5 kW (the maximum power is 6 kW, but the manufacturer does not recommend using the generator in this mode for a long time). The operating time without refueling for this model is almost 9 hours. Generator weight 77 kg.
  • ABP 6-230 VH-BSG - a modernized version of the previous model, featuring an electric starter.
  • ABP 10-230 VH-BSG - industrial open single-phase model recommended by the manufacturer for the main and backup power systems of country cottages, factories, construction sites and shops. Rated power 10 kW, battery life up to 6 hours, weight 140 kg. Equipped with an electric starter.
  • ABP 16-230 VB-BS - differs from the previous model in the increased nominal power to a solid 16 kW. Able to work without refueling for 6 hours. Product weight - 200 kg. Unlike most other Vepr generators equipped with a Honda engine, this variant uses a Briggs-Stratton Vanguard engine.
  • UPS 7/4-T400 / 230 VX - industrial three-phase (400 V) open generator with a power of 4 kW per phase (with a single-phase connection, it provides a power of 7 kW). Manual launch. Battery life is about 2 hours, weight 78 kg.
  • UPS 7/4-T400 / 230 VX-B - differs from the previous version in the increased operating time up to almost 9 hours without refueling, the weight is 80 kg.
  • ABP 7/4-T400 / 230 VH-BSG - differs from the previous model in the electrically installed starter and the weight increased to 88 kg.
  • ABP 10/6-T400 / 230 VH-BSG - industrial open three-phase version with a rated power of 10 kW (6 kW per phase with three-phase connection). Equipped with an electric starter, battery life 6 hours, weight 135 kg.
  • ABP 12-T400 / 230 VH-BSG - a three-phase version with a reinforced phase, providing a power of 4 kW on the main phases and 12 kW on the reinforced one. Operating time without refueling up to 6 hours, electric starter, weight 150 kg.
Image
Image
Image
Image
Image
Image
Image
Image
Image
Image
Image
Image

How to choose?

When choosing a generator, first of all, you need to take into account its such characteristics.

Power

It is this parameter that determines the maximum power of all consumers that can be connected to the device.

Before purchasing, it is important to determine in advance the power rating of the generator you need. To do this, you need to add up the power of all your electrical appliances and multiply the amount by the safety factor (it must be at least 1, 5).

Approximate correspondence of the power to the purpose of the electric generator:

  • 2 kW - for short hikes and backup lighting;
  • 5 kW - for regular tourism on long routes, they can completely feed a small summer house;
  • 10 kW - for country houses and small construction and industrial facilities;
  • 30 kWt - semi-professional option for shops, supermarkets, workshops, construction sites and other business facilities;
  • from 50 kW - professional mini-power plant for large industrial facilities or large shops and office centers.
Image
Image

Battery life

Even the most powerful generator cannot work forever - sooner or later it will run out of fuel. And gasoline models also require technological breaks so that their parts can cool down. The duration of operation before stopping is usually indicated in the documentation for the device. When choosing, it is worth proceeding from the tasks for which the generator is designed:

  • if you need a generator for tourism or a backup system in conditions , when long power outages are not expected, then it is enough to purchase a model with a battery life of about 2 hours;
  • for giving or a small store without refrigerators, 6 hours of continuous work is enough;
  • for power system responsible consumers (supermarket with refrigerators) need a generator that can run for at least 10 hours.
Image
Image

Design

By design, open and closed generators are divided. Open versions are cheaper, cooler and easier to transport, while closed ones are better protected from the environment and produce less noise.

Image
Image
Image
Image

Start method

According to the method of launching mini-power plants, there are:

  • manual - manual launch is well suited for low-powered touring models;
  • with electric starter - such models are launched by pressing a button on the control panel and are well suited for stationary placement;
  • with automatic transfer system - these generators automatically turn on when the mains voltage drops, therefore they are ideal for critical backup power systems.
Image
Image
Image
Image

Number of phases

For a house or a summer residence, the option with single-phase 230 V sockets is enough, but if you plan to connect machines or powerful refrigeration equipment to the network, then you cannot do without a three-phase 400 V output.

The purchase of a three-phase generator for a single-phase network is unjustified - even if you can connect it correctly, you still have to monitor the load balancing between the phases (the load on any of them should not be more than 25% higher than on each of the other two) …