Gasoline Generators HUTER: An Overview Of The Models, What Kind Of Oil To Fill In The Engine Of A Gasoline Electric Generator. What If It Won't Start?

Table of contents:

Video: Gasoline Generators HUTER: An Overview Of The Models, What Kind Of Oil To Fill In The Engine Of A Gasoline Electric Generator. What If It Won't Start?

Video: Gasoline Generators HUTER: An Overview Of The Models, What Kind Of Oil To Fill In The Engine Of A Gasoline Electric Generator. What If It Won't Start?
Video: Первый запуск бензинового генератора. Плюс несколько советов 2024, April
Gasoline Generators HUTER: An Overview Of The Models, What Kind Of Oil To Fill In The Engine Of A Gasoline Electric Generator. What If It Won't Start?
Gasoline Generators HUTER: An Overview Of The Models, What Kind Of Oil To Fill In The Engine Of A Gasoline Electric Generator. What If It Won't Start?
Anonim

It is known that in areas located at a significant distance from large cities, there are still difficulties with the power supply of the home network. To solve them, you will need to use an autonomous power supply. Of the most famous options currently on the Russian market, you can choose gas generator Huter . The small size and weight of the units make it possible to move the device effortlessly and install it anywhere.

Image
Image
Image
Image

Peculiarities

Any Huter gasoline electric generator contains an internal combustion engine, an alternator and a control unit . Such an installation makes it possible to produce electric current by converting mechanical energy into electrical energy. Gas generators from 1 kW to 6.5 kW equipped with an air cooling system, a synchronous generator and with auto start are especially in demand among Russian consumers.

Image
Image
Image
Image

The advantages of power plants manufactured by a company from Germany include the following factors:

  • a wide range of products;
  • good productivity;
  • economical fuel consumption;
  • good quality of the produced current;
  • wide range of operating temperatures;
  • long period of non-stop work;
  • high level of environmental friendliness;
  • small size;
  • solid guarantee.
Image
Image
Image
Image

But there is also small cons - high noise level and improper operation of the sensor responsible for measuring the volume of fuel. If we talk about noise, then, in fact, any Huter gasoline generator makes a lot of noise, and its level sometimes reaches 90 dB. To eliminate this problem, auxiliary sound insulation is used.

Image
Image
Image
Image

Model overview

The Russian market of gasoline power plants can boast of a huge variety of modifications available on it. The most popular at the moment are the following units: Huter DY3000L, Huter DY5000L, Huter DY8000LX and Huter DY6500LX.

Gasoline Generator Huter DY6500LX refers to electrical installations of the category of small-sized, intended for domestic use. It is equipped with a 5 kW engine with a fuel consumption of 1.8 l / h. The gas tank capacity of 22 liters makes it possible to ensure non-stop operation of the unit for 9 hours. A manual or automatic starting method can be used to start the generator. The structure of the gas generator contains such important components as a voltage regulation unit and a short circuit protection complex.

The declared characteristic of external noise is 71 dB. The weight of the unit reaches 84 kilograms.

Image
Image
Image
Image

Huter DY5000L is a mobile gasoline generator for outdoor use. It is equipped with a 4-stroke engine and has a power of 4 kW. Its fuel consumption is 1.5 l / h. A 22-liter gas tank is enough for several hours of non-stop work. The unit is equipped with a forced air cooling system. External noise parameters are in the range of 70-72 dB. The gasoline generator is equipped with an overload protection system and an hour meter that will promptly prompt when to perform maintenance. The weight of the equipment is 77 kilograms.

Image
Image
Image
Image

Gasoline Generator Huter DY3000L - a typical representative of electrical appliances intended for domestic use. Its power is 2.5 kW with a fuel consumption of 1.3 l / h. This sample has a gas tank capacity of 12 liters. This is enough for 10 hours of stable operation of the main consumers of electricity in the house. In comparison with other modifications of the Huter, this gas generator has a fairly low noise level, it equals 67 dB. The generator is easy and simple to transport, and this is favored by its low weight - 43 kilograms.

It will come in handy as a backup source of electricity at a summer cottage or in a small country house. The unit can also be used on hikes or during trips to the bosom of nature.

Image
Image
Image
Image

Gasoline Generator Huter DY8000LX is a representative of the middle segment of power plants operating on liquid fuel. This unit has a power of 6.5 kW. Its fuel consumption is 2 l / h. The fuel tank holds 25 liters. The gas generator can operate for about 8 hours on one tank. During operation, the unit emits a fairly strong noise, the level of which can be higher than 80 dB. The gasoline generator has a mass of 96 kilograms, therefore it is equipped with wheels and handles for moving.

Image
Image
Image
Image

How to choose?

At the moment of choosing any gasoline generator, and Huter in this case is no exception, it is necessary to clearly understand what specific tasks do you need it for … Everyone understands that going on a fishing trip requires a small-sized and not very heavy-weight unit that is capable of providing an electric current to a tape recorder, a small refrigerator - enough for 1 kW, maximum 3 kW.

But when it comes to supplying electricity to several points at the same time, where it is planned to connect several consumers, samples with greater power and productivity should be considered.

For household purposes prefer models for 4-6, 5 kW, the most popular are 5 kW units.

Image
Image
Image
Image

Operating tips

Several useful recommendations associated with the use of a gas generator

  1. In the case of active operation of the power plant, it is necessary keep all deadlines under control , established for the operation of any of the engine components, as well as the life of consumables.
  2. Overhaul must be carried out in a rigid ratio with the permissible service life of the internal combustion engine of the model. Before starting it, check the level and quality of fuel and oil. If there is a need to refuel with oil, then it is necessary to fill it only when the engine is turned off and cold. Be aware that removing the oil filler cap while the engine is running can cause serious injury or burns.
  3. Fill only those types of fuels and lubricants recommended in the technical documentation for your machine. In it, you can also find out the timing of the replacement of all consumables.
  4. Will be needed regularly replacement of oil and air filters , cleaning or installing new spark plugs .
  5. Certain modifications of gas generators are capable of generating electric current for household and industrial voltage. It should be used specifically for the correct devices and do not try to adapt the device operating from 220 V, under a voltage of 380 V, and vice versa.
  6. In some brands of gasoline generators, there are 12 V terminals, which make it possible to charge batteries. However, some owners consider it permissible to use them as a power source for starting a car engine. Doing this is strictly prohibited . due to the fact that during the start of the car engine, high jumps in current parameters appear, which lead to a breakdown of the generator unit.
  7. If you intend to connect electronic computers and other types of complex household appliances, then it is recommended the use of an inverter gas generator , which will be the optimal solution for providing stable power supply to sensitive devices for which voltage surges are dangerous: heating boilers, laptop chargers, computers, sophisticated electronic equipment.
  8. To make it easier to switch your home to a backup power supply, it is advisable to connect the gas generator to the power grid of the house through the ATS - automatic start system.
Image
Image
Image
Image

The user should also pay attention and operating conditions and storage of equipment … The permanent location of the generator must be protected from precipitation and direct sunlight. With all this, the device should not function in a closed room. This is due to the fact that its exhaust gases are very toxic.

It can only be placed on a hard, fairly flat surface, which excludes the risk of foreign objects getting into the ventilation system.

Recommended: