2024 Author: Beatrice Philips | [email protected]. Last modified: 2024-01-07 13:49
Diesel generators FPT-Iveco are of high quality and can be used even in rather difficult conditions. However, for all the perfection of this technique, it must be chosen very carefully. It is necessary to take into account not only general principles, but also the features of specific models.
Features and purpose
When meeting diesel generators FPT-Iveco pay attention right away on the engine of increased power . Italian engineers tried to ensure the maximum service life of their developments. Moreover, it is typical not for well-oiled factory conditions, but for real use, when the environment around a diesel engine is far from ideal.
FPT company carries out its own scientific and technical developments , which can significantly improve the basic properties of the product.
The company even managed to create a complete production cycle, which allows it to guarantee maximum responsibility and teamwork.
The manufacturer declares that all products delivered directly from Europe . At the same time, verified delivery times and optimal prices are also guaranteed. Diesel generators FPT-Iveco are declared as excellent assistants in uninterrupted power supply of the most critical facilities. They use less fuel than competing products of comparable power . And, importantly, total price of Italian diesel generators is comparable to the price offered by the main Russian suppliers.
Specifications
Almost all generators from FPT-Iveco have reliable and adequately functioning temperature sensor . The service interval is at least 600 hours. The latest developments, which have "absorbed" the experience accumulated over many years, this figure can reach 800 hours. 25 basic models of diesel generators of this concern have a main power from 15 to 480 kW. Standby (peak) power can reach 500 kW.
Model overview
The Italian company supplies some of its generators in soundproof enclosures. All of these housings reliably protect electrical components from moisture ingress. A good example of this is GS F3230. These are the main parameters of this diesel generator:
- fuel tank with a capacity of 120 liters;
- fuel consumption at full load - 8, 3 liters;
- fuel consumption at half load - 4, 3 liters;
- work interval between services - 600 hours;
- 3 working phases and additional neutral;
- power in the main (standby) mode - 30 (33) kW.
Noteworthy and generator NEF200 . It is stated that at a distance of 7 m from it, the sound volume does not exceed 75 dB. Fuel consumption at maximum and half load is 44 and 25.6 liters per hour, respectively. The system power in the main mode is 160 kW. In the standby version, it can reach 176 kW.
If we consider the options for the GE series (on a frame, in an open version), then it is worth taking a closer look at NEF75 . The main and peak power here are equal to 60 and 66 kW, respectively. The 4-stroke diesel engine is powered by a 180-liter fuel tank and a cooling circuit that holds 18.5 liters of refrigerant. Electrical protection level - IP23. The generator supplies a current of 400 V and a frequency of 50 Hz.
Criterias of choice
Of course, it is of great importance diesel power , driving the generator unit, because it depends on it whether it will be possible to provide the necessary electricity generation or not. Maintenance at FPT-Iveco at the proper level, and this consideration can be neglected. But what cannot be ignored is generator execution . Outdoor devices must be placed inside a special casing.
For devices installed indoors or operated only in the warm season under sheds, this is not too critical.
Further, it is important to consider characteristics of energy consumers. Power supply for single-phase appliances it is more correct and logical to conduct with the help single-phase generators. But such a need arises mainly at industrial facilities. The main part of household electrical equipment has three-phase execution, and for the same cottage settlements, the optimal choice would be a generator with 3 phases.
The difference can also be due to:
- lighting load (typical for settlements);
- power active load (industrial electric furnaces);
- power inductive load (powerful electric motors);
- thyristor type of load (found mainly at communication centers and at oil production facilities).
Recommended:
Generator Power: 1, 2, 5, 6, 10 KW 220 And 380 Volts, Models 15, 50, 60, 100 KW And Other Power. How To Calculate The Required Power?
Correctly selected generator power is the absence of overpayments for unnecessary coolness of the unit and one hundred percent confidence that it will help out when darkness overtakes. 1, 2, 5, 6, 10 kW 220 and 380 volts, models 15, 50, 60, 100 kW and other power: how much is enough for basic needs, how is the voltage related to the generator power? How to calculate the required power?
Diesel Generator Power: 2, 3, 4, 5 KW, 6, 7 And 8, 10-15 KW, 20, 30-50 KW, 60 And 100-200 KW, 500 KW And Power Plants With Other Power
When purchasing an autonomous power plant, you should calculate in advance the required power of diesel generators, so as not to overpay for fuel and not find yourself in a situation where the backup power source does not withstand the minimum demands. In what cases are models for 5, 7 and 8 kW, 10-15 kW, 30-50 kW useful?
Heat Gun Temperature: Maximum Heating Temperature At The Outlet. What Is The Minimum Temperature It Gives Out? Work Taking Into Account The Temperature Of The Hot Air Gun
Heat gun temperature: maximum heating temperature at the outlet. What is the minimum temperature it gives out? What work, taking into account the temperature of the hot air gun, can be done - read about this in the publication
Smokehouse Thermometer: Mechanical Thermostat, Temperature Sensor For Hot Smoking Options, How To Choose A Temperature Sensor
A smokehouse thermometer must be of high quality and correctly selected. How to choose a mechanical thermostat for a home smokehouse yourself? What are the main types of smoker thermometers?
Temperature For Peppers: Night And Day, In The Open Field And In The Greenhouse. At What Temperature Are They Planted And What Do The Peppers Withstand? Minimum And Optimum Growing Temperature
Temperature for peppers plays a big role. What should be the night and day temperature in the open field and in the greenhouse? At what temperature are they planted and what do the peppers withstand? What is the minimum and optimum growing temperature?