Diesel Three-phase Generators: An Overview Of Models For 15 KW, 5 KW, 10 KW And Other Power. How To Connect?

Table of contents:

Video: Diesel Three-phase Generators: An Overview Of Models For 15 KW, 5 KW, 10 KW And Other Power. How To Connect?

Video: Diesel Three-phase Generators: An Overview Of Models For 15 KW, 5 KW, 10 KW And Other Power. How To Connect?
Video: BlackStone OFB 4000 D Single-Phase Diesel Generator - Nominal Power 2.8 kW - Product Introduction 2024, April
Diesel Three-phase Generators: An Overview Of Models For 15 KW, 5 KW, 10 KW And Other Power. How To Connect?
Diesel Three-phase Generators: An Overview Of Models For 15 KW, 5 KW, 10 KW And Other Power. How To Connect?
Anonim

Power supply via main lines is not always reliable, and in some places it is not available at all. Therefore, you need to know everything about three-phase diesel generators. These valuable devices can supply electricity to a remote community or become a backup in case of outages.

Image
Image

Peculiarities

It should be said right away that diesel three-phase generators can be used both for domestic needs and for small industrial enterprises. As such, they are even preferable, because they provide more power than gasoline counterparts. And therefore, the high price of diesel vehicles is fully justified.

The main specificity of diesel generators with 3 working phases is also:

  • the use of relatively inexpensive fuel;
  • increased efficiency;
  • the ability to connect to several energy consumers at once;
  • resistance to significant loads and even drops in the network;
  • mandatory presence of a bundle with a three-phase network;
  • commissioning only by people with a special permit.
Image
Image

Model overview

A good example of a 5 kW power generator is LDG6000CL-3 from Amperos … But it is important to understand that 5 kW here is the maximum power. The nominal figure is 4.5 kW.

The open design will not allow this device to be used outdoors.

From a fuel tank with a capacity of 12, 5 liters, 1, 3 liters of fuel will be taken hourly.

Image
Image
Image
Image

Choosing a 6 kW model, you should focus on TCC SDG 6000ES3-2R … This generator comes with an enclosure and an electric starter, which is very convenient.

Other properties worth noting:

  • power factor 0.8;
  • 1 working cylinder;
  • air cooling;
  • twisting speed 3000 rpm;
  • lubrication system with a volume of 1, 498 liters.
Image
Image

A decent diesel 8 kW is, for example, " Azimut AD 8-T400 " … Peak power can reach 8, 8 kW. Installed a tank with a volume of 26.5 liters. Fuel consumption per hour - 2.5 liters. The device can supply 230 or 400 V.

Image
Image

Among devices with a power of 10 kW, it is worth paying attention to TCC SDG 10000 EH3 … Starting the synchronous generator into operation is provided by an electric starter. The two-cylinder diesel engine helps the dynamo generate 230 or 400 V. The air-cooled engine spins at up to 3000 rpm. At 75% load, it will consume 3.5 liters of fuel per hour.

Image
Image

Power of 12 kW develops " Source AD12-T400-VM161E " … This generator produces a current of 230 or 400 V. The amperage reaches 21, 7 A. As in previous models, air-cooled is used. For an hour of operation, when loading at ¾, 3.8 liters of fuel will be taken from the tank.

Image
Image

It is also worth noting and Genese DC15 driven by YangDong … The motor rotation speed is 1500 rpm. Moreover, it is equipped with a liquid cooling system. The generator is of the synchronous type and produces a current with a frequency of 50 Hz, which can be used in domestic conditions.

The weight of the Russian product is 392 kg.

Image
Image

But quite a few people need 15 kW diesel generators. Then it will do CTG AD-22RE … The device is started by an electric starter and produces 17 kW in peak mode. Fuel consumption at 75% loading reaches 6.5 liters. At the same time, the capacity of the fuel tank is 80 liters, so it is definitely enough for 10-11 hours.

Image
Image

Alternatively, you can consider Hertz HG 21 PC … The peak power of the generator reaches 16.7 kW. The motor rotates at a speed of 1500 rpm and is cooled by a special fluid system. Fuel tank capacity - 90 liters.

The mass of the Turkish product is 505 kg.

Image
Image

If a 20 kW generator is required, MVAE AD-20-400-R … Peak short-term power is 22 kW. An hour will consume 3, 9 liters of fuel. Electrical protection level - IP23. The current strength reaches 40A.

Image
Image

But in some cases it is required to provide a power of 30 kW. Then it will do Airman SDG45AS … The current of this generator is 53 A. The designers have carefully thought out liquid cooling. Fuel consumption per hour reaches 6.4 liters (at 75%), and the tank capacity is 165 liters.

Image
Image

Alternatively, you can consider " PSM AD-30 " … This generator will give out a current of 54 A, the voltage will be 230 or 400 V. From a tank with a capacity of 120 liters per hour, 6, 9 liters of fuel are taken.

The mass of the synchronous generator from the PSM is 949 kg.

This Russian product comes with a one-year warranty.

Image
Image

How to connect?

As important as the characteristics of a diesel generator set are in themselves, they mean nothing without a mains connection. The wiring diagram is simple and allows you to change almost nothing in the home wiring. First, turn off the 380 V input circuit breaker , thus turning off all devices. Then they put an updated four-pole machine in the dashboard … The terminals of its outputs are connected to the taps for all the necessary devices.

Image
Image

Then they work with a cable that has 4 cores. It is brought to a new machine, and each core is connected to the corresponding terminal. If the circuit also includes an RCD, then the switching should take into account the features of the wiring of the conductors … But the connection via an additional automatic distribution machine does not suit everyone.

Often the generator is connected through a switch (the same machine, but with 3 working positions).

Image
Image

In this case, the busbars are connected to one, the high-voltage supply conductors to the other set of poles. The main contact assembly of the circuit breaker is the one from which the conductors are brought directly to the load. The switch is thrown to the input from the high-voltage line or from the generator. If the switch is in the middle, the electrical circuit is broken. But manual selection of a power source is not always convenient.

Automatic load transfer always activates the control unit and a pair of contactors. The starters are cross-connected. One unit is made on the basis of a microprocessor or a transistor assembly … He is able to recognize the loss of power in the main network, disconnection of the consumer from it. The contactor will also work out the situation with switching devices to the generator outlet.